Intel® Graphics - BETA Windows® 10 DCH Drivers. This download installs the Intel® Graphics Beta Driver for 6th, 7th, 8th, 9th, 10th, 11th generation, Apollo Lake, Gemini Lake, Amber Lake, Whiskey Lake, Comet Lake, and Lakefield (27.20.100.9077). Driver: Windows 10, 64-bit. 27.20.100.9077 Latest: 12/9/2020: Intel® Extreme Tuning Utility. . Ambulance Aide/Driver -. Combat Medic -. Emergency Med Care Specialist -. Health Care Specialist -. Immunology/Allergy Specialist -. Litter Bearer.

COMAT CT-System are a multifunction modular time delay relays system.

Combat Driver Badge

COMAT CT-System

The COMAT CT System is modular:

The time delay relays and monitoring relays consist of the plug-in Comat CT electronic module and an 11-pole Comat CT output relay.
Both system components can be combined freely with one another.
This allows the equipment to be optimally selected for specific use.
Subsequent modifications, for example a charge from mechanical contacts to solid-state outputs, are possible at any time by simple reconnection.
This provides the user with a complete, universal system, whose high flexibility is unique throughout the world.

The modules:

The system socket C12B0 serves as a basis for the vibration-free reception of the electronic module.
It has a 4-pole module slot in which the Comat CT-module –also without output relay– locks in such a way that it is vibration-free.
Contact is via twin knife contacts which ensure optimal contact reliability.
With the A2-connector C-A2 plug-in flush in the socket, the neutral conductor (N / –) can be connected as a 10A bus from socket to socket.
This considerably reduces wiring work.
Robust terminals for cross-sections up to 4mm² and generous labeling facilities are other advantages of this practical Comat system socket.
As variants to the standard socket C12B0, two identical sockets, but with printed device diagram, are available (C12B1/2).
By clearly identifying the connections, these sockets ensure rapid, error-free and therefore economical wiring.
When a service is required, they facilitate fault location.
The Comat CT module demonstrates Comat’s practical experience in the area of industrial electronics.
All control and display elements are arranged on the front and are labeled in a self explanatory manner for international use.
The values set are also clearly legible when the module has been installed.
Printed diagrams explain the functions, and the connection scheme directly indicates the appropriate terminals in the system socket.
A transparent front cover provides protection from unauthorized misadjustment and additionally locks the module onto the output relay.
Triggering is performed with the operating voltage (L1 or +). Hence, no potential-free contacts are required.
Triggering complies with the machine standards. A parallel connection of other users to B1 is admissible.
The 2 voltage ranges UC110-240V and UC24-48V have been chosen by Comat to ensure a high level of reliability in triggering.
They permit use with an AC or DC supply and optimal adaptation to the operating conditions of modern controls.
In case of an even broader voltage range, e.g. 24-240V it is often possible to achieve only currents of a few 100µA in the trigger circuit B1 with simultaneous low threshold voltages to less than 20V.
This may lead to unintentional triggering due to capacitive / inductive pickups, or faulty switching may occur owing to sufficiently loaded control contacts.
During operation, 50V are readily measured on open-ended lines.
The consumption of the Comat CT modules comes to less than 1W.
The output relays have the complete device diagram, the performance data and the complete order no. on the front, supported by a colour code, which indicates an AC coil with red and a DC coil with blue.
The .1 and .2 relays have a safety manual operation facility as a standard feature, which switches the contacts only after a lock has been released (two hand principle).
The standard contacts .1 and .3 have proved their worth millions of times in heavy current applications.
The contact material AgNi permits a large switching range and thanks to generous dimensioning achieves a high number of cycles.
With its high breaking capacity of up to 10A/400V, this contact is a reliable all round contact for use both in mains circuits and in the lower voltage range from 12V/10mA.
The twin contacts .2 and .4 switch every circuit with two independent reeds.
Compared with single contacts, they provide up to 100 times greater safety with regard to the level of possible faulty switchings.
In spite of their high breaking capacity of up to 6A/250V, these contacts are particularly suitable for low switching currents and switching voltages down to 1mA/6V.
The solid-state relays are used instead of mechanical contacts.
In the standard version .5, the relay has a potential-free output which switches an AC or DC load in the same way as a mechanical contact.
However, it functions without bounce or wear, withstands overloads, has short circuit protection and has a practically unlimited life even with full output load.
Preferred applications are high switching frequency, for example as repeat cycle timers, flashing bars with bulb load or extreme inductive loads, for example large solenoid valves, couplings, motors, etc.
An additional protective wiring of the output or of the load is not necessary in these Comat relays for any application.
They are completely insensitive in an aggressive atmosphere, for example in the chemical industry, in waste water treatment plants, etc.

Comat CT SystemSeriesTime RangeSocket typeWidth
mm
Contacts

Economy-Timer

3 functions, voltage controlled, Output LED.

CT30

0,25s -30min38Any choice from Industrial Relays Series C3…

Universal Timer

7 functions, voltage controlled, time lapse display, blinking.

CT32

0,15s -60min38Any choice from Industrial Relays Series C3…

Universal Timer

12 functions, voltage controlled, time lapse display, blinking,
high setting accuracy by dial graduation 1:5.

CT33

30ms -60h38Any choice from Industrial Relays Series C3…

Universal repeat cycle timer

Pulse or pause start. t1/t2 separately set table.
Time lapse display t1/t2.

CT36

2x 50ms -60h38Any choice from Industrial Relays Series C3…

Typical time functions of COMAT, MULTICOMAT relays:

Delay functions:

  • E: On delay
  • A: Off delay
  • F: On and off delay

Shot timing modes:

  • W: One shot leading edge
  • N: One shot trailing edge
  • Q: One shot and trailing edge

Pulse shaping:

  • K: Pulse shaping
  • L: Pulse shaping, retrigger
  • M: Pulse shaping

Blinker functions:

  • B: Blinker, pulse start
  • B1: Blinker, pulse start, trailing pulse
  • B2: Blinker, interval start

Delayed pulse:

  • G: On delay single shot
  • H: On delay single shot

Repeat cycle timer:

  • I: Repeat cycle timer, pulse start
  • P: Repeat cycle timer, interval start

Special functions:

  • Y: Star-delta timer
  • X1: Restart delay

Pulse sequence monitoring:

  • U: Pulse sequence monitoring
  • V: Pulse sequence monitoring

Combat Diver School

Combat

All relays … (selected by type):

Industrial, interface and installation relays:Timers:Monitoring relays:Compact PLC:
Interface relays
Miniature industrial relays
Standard industrial relays
Industrial relays LONG LIFE
DIN Relays
Solid-state relays (SSR)
Miniature Contactor
Step-on Step-off / Power Relays
Staircase Lighting Timer
Installation Relays for central control
Plug-in time cubes for industrial relays
The Comat CT System
Plug-in time relays
DIN time relays
Multicomat Programmable Plug-in
time delay relays RS, C, CX-series
Multicomat specially timers, Amplifier Relays,
Pulse Shapers, Preset Counters
Voltage monitor
Current monitoring relays
Three-phase monitoring
DC voltage / DC current monitor
Thermo protection relays
SMS Relay
Comat BoxX

more relays type … (alphabetical):

A… up to B…
BoxX controller, Relays, Time Delay Relays, Stair case lighting timer
C… up to C5…
Power miniature relays, LONG LIFE signal and control relays, Time Delay Relays
C6… up to C9…
Timers, Relays, Time Delay Relays, Miniature industrial relay, Control relay
CA… up to CY…
Relays, Time Delay Relays, voltage and current monitor, interface relays
E… up to Z…
Railway Relays, Time Delay Relays, Measuring and monitoring equipments, Thermo protection relay
List of replacement and compatible industry, control, monitoring, time delay relays, sockets MULTICOMAT, COMATFunctions and descriptions for time delay relaysData sheets, documentations and catalogs about products BoxX controller, EDL, Timers, Industrial relays, Monitoring relays, Compact Controller

Nothing found? or you want more information about COMAT CT-System timers or another products, please send us a fax: +49 7082 940001, or email to: Inquiry to Kühn Controls… we continue to search for you…

Legal notice • Startsite • Sitemap • Kühn Controls AG • Contact

This Site is created by Kühn Controls AG, all rights reserved.

As a NZ Army Combat Driver you will operate all of our general service vehicles, from motorbikes through to articulated trucks. You will be a member of the Royal New Zealand Army Logistics Regiment (RNZALR), and within that you’ll operate in a Combat Service Support unit as part of a close-knit transport section (four to six vehicles).

You will be trained to operate your vehicle by day and night, in all weather conditions and terrain, from convoy driving on sealed state highways to tactical, off-road navigation. You will drive, operate, service and maintain your vehicles, gaining a range of licences, licence endorsements, and NZQA unit standards towards New Zealand Road Transport Industry National Certificates.

The New Zealand Army uses a huge variety of vehicles: motorbikes, cars, the Pinzgauer Light Operating Vehicle, the Unimog U1700L truck, the new technologically advanced family fleet of MAN Medium Heavy Operational Vehicles (MHOV,) and Heavy Equipment Transport (HET). You will be taught how to safely operate all these vehicles in all kinds of operational situations, such as passenger transport, distribution of supplies and hazardous goods transportation. You will also learn basic mechanic skills for operator servicing and routine maintenance. Drivers keyboard.